The SOETECK SY-T Series Winner Pro+ UPS, Online High-frequency UPS, 1kVA-10kVA, Tower Mount, PF0.9, True Double Conversion is a versatile and energy-efficient power protection solution. With true double-conversion technology, a wide input voltage range of 110V to 300V, and high PF 0.9 output, it ensures clean and reliable power delivery. Ideal for IT systems, healthcare facilities, and communication infrastructure, this UPS offers ECO mode for energy savings (1-3kVA models) and modular battery configurations for flexible runtime. Enhanced with remote monitoring capabilities and intuitive LCD displays, it provides seamless performance for critical operations.
No data available |
The SOETECK SY-T Series Winner Pro+ UPS, Online High-frequency UPS, 1kVA-10kVA, Tower Mount, PF0.9, True Double Conversion is a next-generation power protection solution tailored to meet the needs of mission-critical systems. With capacities ranging from 1kVA to 10kVA, this UPS provides a robust, efficient, and reliable power backup solution for diverse applications, including IT networks, banking systems, healthcare facilities, and communication infrastructure. Its advanced true double-conversion technology ensures clean, consistent power delivery, safeguarding sensitive equipment from surges and fluctuations.
Engineered with an intuitive design, the SOETECK SY-T Series Winner Pro+ UPS features a wide input voltage range of 110V to 300V, making it adaptable to unstable grids and generator compatibility. The system achieves a high output power factor of 0.9, optimizing energy utilization and reducing operational costs. Additionally, the ECO mode available for 1-3kVA models ensures energy efficiency during low-load operations, making it an environmentally friendly choice for smaller setups.
With its modular battery design, this UPS supports flexible configurations to match specific runtime requirements. Optional SNMP cards allow for seamless remote monitoring and management through USB or RS232 interfaces, enhancing operational visibility. Featuring advanced LCD indicators, the UPS provides real-time updates on load, battery health, and system performance. The SOETECK SY-T Series Winner Pro+ UPS is a reliable, scalable, and user-friendly solution designed to deliver long-term value and peace of mind.
The SOETECK SY-T Series Winner Pro+ UPS, Online High-frequency UPS, 1kVA-10kVA, Tower Mount, PF0.9, True Double Conversion offers a wide range of models to suit different operational needs. The 1kVA, 2kVA, and 3kVA models are optimized for smaller environments, featuring energy-efficient ECO mode to reduce power consumption. For larger setups, the 6kVA and 10kVA models deliver extended runtime and higher performance, ensuring reliable operation in demanding scenarios. Each model features a wide input voltage range of 110V-300V, high PF 0.9 output, and modular battery configurations for flexible runtime options. Optional SNMP capabilities and advanced LCD displays further enhance the user experience, making this UPS series an ideal choice for critical applications.
Models | Power Rating | Input Voltage Range | Output Voltage Range | Efficiency | Wiring |
---|---|---|---|---|---|
N/A | 1000VA / 900W | 60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%) | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | 88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode ) | 1 phase + PE |
N/A | 2000VA / 1800W | 60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%) | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | 88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode ) | 1 phase + PE |
N/A | 3000VA / 2700W | 60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%) | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | 88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode ) | 1 phase + PE |
N/A | 6000VA / 5400W | 60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%) | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | 88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode ) | 1 phase + PE |
N/A | 10000VA / 9000W | 60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%) | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | 88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode ) | 1 phase + PE |
Capacity | 1000VA/900W ; 2000VA/1800W ; 3000VA/2700W ; 6000VA/5400W ; 10000VA/9000W |
Nominal Voltage | 110/115/120/127VAC or 208/220/230/240VAC ; 208/220/230/240VAC |
Input Voltage Range | 60-145 VAC or 120-300 VAC (Based on load at 50%) 90-145 VAC or 180-300 VAC (Based on load at 100%) ; 110-300 VAC (Based on load at 50%) 176-300 VAC (Based on load at 100%) |
Frequency Range | 40Hz ~ 70 Hz / 46Hz ~ 54 Hz or 56Hz ~ 64 Hz |
Power Factor | ≧ 0.99 @ Nominall Voltage (100% load) |
Output Voltage | 110/115/120/127VAC or 208/220/230/240VAC ; 208/220/230/240VAC |
Voltage Regulation | ± 1% |
Frequency Range (Synchronized Range) | 47~ 53 Hz or 57 ~ 63 Hz / 46Hz ~ 54 Hz or 56Hz ~ 64 Hz |
Frequency range (Battery mode) | 50 Hz or 60Hz ± 0.5% / 50 Hz or 60Hz ± 0.1 Hz |
Current Crest Ratio | 3:1 |
Harmonic Distortion | ≤ 3% THD (linear load), ≤ 6% THD (Non-linear load) ; ≤ 3% THD (Linear load); ≤ 5% THD (Non-linear Load) |
Transfer Time AC Mode to Battery Mode | Zero |
Transfer Time Inverter to Bypass | 4 ms (Typical) / Zero |
Waveform (Battery mode) | Pure sine wave |
AC mode | 88% / 89% / 90% / 92% / 93% |
Battery mode | 83% / 87% / 88% / 90% / 91% |
Battery Type | 12 V / 9 Ah |
Numbers | 2/3/4/6/16/20 |
Typical Recharge Time | 4 hours recover to 90% capacity / 9 hours recover to 90% capacity |
Charging Current (max.) | 1A / 1A / 2A |
Charging Voltage | 27.4 VDC ±1% / 41.0 VDC ±1% / 54.7 VDC ±1% / 82.1 VDC ±1% / 82.1 VDC ±1% / 218.4 VDC ±1% / 273VDC ±1% / 218.4 VDC±1% / 273VDC ± 1% |
Battery type | Depending on applications |
Numbers | 3/6/6/16~20 (Adjustable) |
Charging Current (max.) | 1.0A/2.0A/4.0A/6.0 A ; 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries) |
Charging Voltage | 41.0 VDC ±1% / 82.1 VDC ±1% / 82.1 VDC ±1% / 273 VDC ±1% (Based on 20pcs batteries) |
LCD | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continuously sounding |
D * W * H (mm) | 282 x 145 x 220 / 397 x 145 x 220 / 397 x 145 x 220 / 421 x 190 x 318 / 421 x 190 x 318 / 369 x 190 x 688 / 442 x 190 x 688 |
Net weight (kg) | 9.8/11.4/17/26.2/27.6/61/74/66/76 |
D * W * H (mm) | 282 x 145 x 220 / 397 x 145 x 220 / 369 x 190 x 318 / 442 x 190 x 318 |
Net weight (kg) | 4.4/6.8/7.6/12/16 |
Humidity | 20-90 % RH @ 0- 40°C (Non-condensing) ; 0-95% RH @ 0-50°C (non-condensing) ; 0-95% RH @ 0-40°C (non-condensing) |
Noise Level | Less than 50dB @ 1 meter ; Less than 55dB @ 1 meter ; Less than 58dB @ 1 meter |
Smart RS-232 / USB | Supports Windows ® 2000/2003/XP/Vista/2008, Windows ® 7/8, Linux, Unix, and MAC |
Optional SNMP | Power management supports SNMP management and network management |
We offer 24/7 customer support—not just to sell products, but to provide comprehensive assistance.
Our dedicated team is always ready to help with quotes, tailored consultations, and expert advice on product selection.
If convenient, please share your industry background or specific application, along with the products and services you’re interested in.This information will help us provide you with a more personalized solution and accurate quote.
We value every customer’s voice and look forward to discussing how we can provide the best solutions for your business.
© 2024 SOETECK, Inc. All rights reserved