SOETECK delivers professional UPS system solutions for power protection needs ranging from edge computing nodes to hyperscale data centers. Our customized services are tailored to your actual business scenarios, featuring modular design, intelligent redundancy configuration and energy efficiency optimization to build highly reliable and available power protection systems. Expert engineering teams provide end-to-end services from solution design to deployment, ensuring uninterrupted business continuity.

Pedido por:

SOETECK SY-T Series UPS, Online High-frequency UPS, 400kVA-2000kVA, Tower, PF1, True Double Conversion

The SOETECK SY-T Series UPS, Online High-frequency UPS, 400kVA-2000kVA, Tower, PF1, True Double Conversion offers unparalleled power protection for mission-critical systems. With a three-phase input/output design, 98.5% efficiency in ECO mode, and flexible battery configurations, it guarantees operational reliability....
Modelos
ModelosPotencia nominalRango de tensión de entradaRango de tensión de salidaEficaciaCableado
SYT400400kVA / 400kVA304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
SYT500500kVA / 500kVA304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
SYT600600kVA / 600kVA304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
SYT10001000kVA / 1000kW304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
SYT15001500kVA / 1500kW304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
SYT20002000kVA / 2000kW304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out

SOETECK SY-T Series Online High-frequency UPS, 100-300kVA, Tower, PF1

The SOETECK SY-T Series Online High-frequency UPS, 100-300kVA, Tower, PF1 provides reliable, energy-efficient power protection for critical systems. Supporting three-phase input and output, it delivers a wide input voltage range of 110-300V and up to 98.5% efficiency in ECO mode. With modular, pluggable power modules,...
Modelos
ModelosPotencia nominalRango de tensión de entradaRango de tensión de salidaEficaciaCableado
SYT100kVA100kVA / 100kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
SYT120kVA120kVA / 120kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
SYT180kVA180kVA / 180kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
SYT200kVA200kVA / 200kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
SYT240kVA240kVA / 240kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
SYT300kVA300kVA / 300kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out

SOETECK SY-T Series Online High-frequency UPS, 10-60kVA, Tower, PF1

The SOETECK SY-T Series Online High-frequency UPS, 10-60kVA, Tower, PF1 offers robust and efficient power protection for mission-critical systems. With true double-conversion technology, a power factor of 1.0, and three-phase input/output support, it ensures clean and reliable power delivery. Its wide input voltage ran...
Modelos
ModelosPotencia nominalRango de tensión de entradaRango de tensión de salidaEficaciaCableado
SYT10kVA10kVA / 10kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out; 3 phase in, 1 phase out; 1 phase in, 1 phase out
SYT20kVA20kVA / 20kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out; 3 phase in, 1 phase out; 1 phase in, 1 phase out
SYT30kVA30kVA / 30kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase + N + PE
SYT40kVA40kVA / 40kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase + N + PE
SYT60kVA60kVA / 60kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase + N + PE

SOETECK SY-T Series Online High-frequency UPS, 6kVA/10kVA, Tower, PF1, True Double Conversion

The SOETECK SY-T Series Online High-frequency UPS, 6kVA/10kVA, Tower, PF1, True Double Conversion provides reliable and efficient power protection for critical systems. Supporting single-phase input and output, it delivers up to 94% efficiency in AC mode and features a wide input voltage range of 110V to 300V. With low...
Modelos
ModelosPotencia nominalRango de tensión de entradaRango de tensión de salidaEficaciaCableado
SYT6kVA6kVA/6kW110~300VCA (± 3%) con carga de 50%; 176~300VCA (± 3%) con carga de 100%Nominal: 208/220/230/240 VCA94% (modo CA) ; 98.5% ( modo ECO) ; 92% ( modo batería )1 fase de entrada, 1 fase de salida
SYT10kVA10kVA/10kW110~300VCA (± 3%) con carga de 50%; 176~300VCA (± 3%) con carga de 100%Nominal: 208/220/230/240 VCA94% (modo CA) ; 98.5% ( modo ECO) ; 92% ( modo batería )1 fase de entrada, 1 fase de salida

SOETECK SY-T Series Online High-frequency UPS, 1kVA/2kVA/3kVA, Tower Mounted, PF1

The SOETECK SY-T Series Online High-frequency UPS, 1kVA/2kVA/3kVA, Tower, PF1, True Double Conversion is a compact, high-performance UPS solution designed for critical applications. Supporting single-phase input and output, it delivers clean and stable power with a power factor of 1.0. With up to 97% efficiency in ECO...
Modelos
ModelosPotencia nominalRango de tensión de entradaRango de tensión de salidaEficaciaCableado
SYT1K1000VA / 1000W110~300 VAC(Based on load at 50%); 160~300 VAC (Based on load at 100%)Nominal: 200/208/220/230/240 VAC≧ 92% or ≧ 94% at full charged battery ( AC mode ) ; ≧ 96% at full charged battery ( ECO mode ) ; ≧ 86% or ≧ 91% ( Battery mode )1 phase + PE
SYT2K2000VA / 2000W110~300 VAC(Based on load at 50%); 160~300 VAC (Based on load at 100%)Nominal: 200/208/220/230/240 VAC≧ 92% or ≧ 94% at full charged battery ( AC mode ) ; ≧ 96% at full charged battery ( ECO mode ) ; ≧ 86% or ≧ 91% ( Battery mode )1 phase + PE
SYT3K3000VA / 3000W110~300 VAC(Based on load at 50%); 160~300 VAC (Based on load at 100%)Nominal: 200/208/220/230/240 VAC≧ 92% or ≧ 94% at full charged battery ( AC mode ) ; ≧ 96% at full charged battery ( ECO mode ) ; ≧ 86% or ≧ 91% ( Battery mode )1 phase + PE

SOETECK SY-T Series Winner Pro+ UPS, Online High-frequency UPS, 1kVA-10kVA, Tower Mount, PF0.9

The SOETECK SY-T Series Winner Pro+ UPS, Online High-frequency UPS, 1kVA-10kVA, Tower Mount, PF0.9, True Double Conversion is a versatile and energy-efficient power protection solution. With true double-conversion technology, a wide input voltage range of 110V to 300V, and high PF 0.9 output, it ensures clean and relia...
Modelos
ModelosPotencia nominalRango de tensión de entradaRango de tensión de salidaEficaciaCableado
SYTWinner Pro+1kVA1000VA / 900W60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%)Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase + PE
SYTWinner Pro+2kVA2000VA / 1800W60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%)Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase + PE
SYTWinner Pro+3kVA3000VA / 2700W60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%)Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase + PE
SYTWinner Pro+6kVA6000VA / 5400W60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%)Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase + PE
SYTWinner Pro+10kVA10000VA / 9000W60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%)Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase + PE

SOETECK SY-T Series Winner Pro UPS, Online High-frequency UPS, 1kVA-10kVA, Tower Mount, PF0.9

The SOETECK SY-T Series Winner Pro UPS, Online High-frequency UPS, 1kVA-10kVA, Tower Mount, PF0.9 is a high-performance power solution designed for critical applications. Its wide input voltage range of 110V–300V, advanced PF 0.9 output, and energy-saving ECO mode make it ideal for small to large-scale setups. With fle...
Modelos
ModelosPotencia nominalRango de tensión de entradaRango de tensión de salidaEficaciaCableado
SYT1kVA1000VA/900W110-300VAC at 50% load; 160-280 VAC or 170-300 VAC at 100% loadNominal: 208/220/230/240 VCA88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase + PE
SYT2kVA2000VA/1800W110-300VAC at 50% load; 160-280 VAC or 170-300 VAC at 100% loadNominal: 208/220/230/240 VCA88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase + PE
SYT3kVA3000VA/2700W110-300VAC at 50% load; 160-280 VAC or 170-300 VAC at 100% loadNominal: 208/220/230/240 VCA88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase + PE
SYT6kVA6000VA/5400W110-300VAC at 50% load; 160-280 VAC or 170-300 VAC at 100% loadNominal: 208/220/230/240 VCA88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase + PE
SYT10kVA10000VA/9000W110-300VAC at 50% load; 160-280 VAC or 170-300 VAC at 100% loadNominal: 208/220/230/240 VCA88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase + PE

SOETECK SY-T Series UPS, Online High-frequency UPS, 10kVA-30kVA, Tower Mount, PF0.8

The SOETECK SY-T Series UPS, Online High-frequency UPS 10kVA-30kVA provides true double-conversion power protection with PF0.8 efficiency. Designed for critical applications, it features a wide input range of 190-520VAC, 50/60Hz frequency conversion, and advanced DSP technology, ensuring reliable, clean, and stable pow...
Modelos
ModelosPotencia nominalRango de tensión de entradaRango de tensión de salidaEficaciaCableado
SYT10kVA10kVA / 8kW190-520 VAC (3-phase) at 50% load; 305-520 VAC (3-phase) at 100% loadNominal: 208/220/230/240 VCA88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 fase de entrada, 1 fase de salida
SYT15kVA15kVA / 12kW190-520 VAC (3-phase) at 50% load; 305-520 VAC (3-phase) at 100% loadNominal: 208/220/230/240 VCA88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 fase de entrada, 1 fase de salida
SYT20kVA20kVA / 16kW190-520 VAC (3-phase) at 50% load; 305-520 VAC (3-phase) at 100% loadNominal: 208/220/230/240 VCA88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 fase de entrada, 1 fase de salida
SYT30kVA30kVA / 24kW190-520 VAC (3-phase) at 50% load; 305-520 VAC (3-phase) at 100% loadNominal: 208/220/230/240 VCA88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 fase de entrada, 1 fase de salida

SOETECK ST-RT Series, Online High-Frequency UPS, 10kVA-60kVA, Rack/Tower-mounted, 3 Phase In & Out

The SOETECK ST-RT Series, Online High-Frequency UPS 10kVA-60kVA delivers true double-conversion power protection with 3 Phase In / 3 Phase Out architecture, ensuring uninterrupted power for critical systems. With PF1 efficiency, 95.5% ECO mode, and flexible rack/tower-mounted installation, it is designed for reliable a...
Modelos
ModelosPotencia nominalRango de tensión de entradaRango de tensión de salidaEficaciaCableado
SYRT10kVA10kVA/10kW190-520VAC ( 3-phase ) at 50% load; -305-478VAC ( 3-phase) at 100% load3 x 360/380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
SYRT15kVA15kVA/15kW190-520VAC ( 3-phase ) at 50% load; -305-478VAC ( 3-phase) at 100% load3 x 360/380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
SYRT20kVA20kVA/20kW190-520VAC ( 3-phase ) at 50% load; -305-478VAC ( 3-phase) at 100% load3 x 360/380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
SYRT30kVA30kVA/30kW190-520VAC ( 3-phase ) at 50% load; -305-478VAC ( 3-phase) at 100% load3 x 360/380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
SYRT40kVA40kVA/40kW190-520VAC ( 3-phase ) at 50% load; -305-478VAC ( 3-phase) at 100% load3 x 360/380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
SYRT60kVA60kVA/60kW190-520VAC ( 3-phase ) at 50% load; -305-478VAC ( 3-phase) at 100% load3 x 360/380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out

SOETECK Serie ST-RT, SAI de alta frecuencia en línea, 6kVA/10kVA, montaje en bastidor/torre, PF1

The SOETECK ST-RT RT Series, Online High-frequency UPS 6kVA/10kVA offers PF1 power factor, true double conversion technology, and flexible rack/tower-mounted installation. With a wide input voltage range (110-300VAC), 98.5% efficiency in ECO mode, and zero transfer time for AC to Battery Mode, it delivers reliable and...
Modelos
ModelosPotencia nominalRango de tensión de entradaRango de tensión de salidaEficaciaCableado
SYRT6kVA6000VA / 6000W110~300VCA (± 3%) con carga de 50%; 176~300VCA (± 3%) con carga de 100%Nominal: 208/220/230/240 VCA94% (modo CA) ; 98.5% ( modo ECO) ; 92% ( modo batería )1 fase de entrada, 1 fase de salida
10000VA/10000W10000VA / 10000W110~300VCA (± 3%) con carga de 50%; 176~300VCA (± 3%) con carga de 100%Nominal: 208/220/230/240 VCA94% (modo CA) ; 98.5% ( modo ECO) ; 92% ( modo batería )1 fase de entrada, 1 fase de salida