ModelsPower RatingInput Voltage RangeOutput Voltage RangeTransfer TimeCharging PeriodWeight
SYSR-10001000VA / 800W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms max6-8 hours recover to 90% capacity16.2 kg
SYSR-15001500VA / 1200W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms max6-8 hours recover to 90% capacity19.2 kg
SYSR-20002000VA / 1600W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms max6-8 hours recover to 90% capacity26.6 kg
SYSR-30003000VA / 2400W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms max6-8 hours recover to 90% capacity28.5 kg
SYSR-50005000VA / 4000W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms max6-8 hours recover to 90% capacity39.0 kg
SYSR-1000L1000VA / 800W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms maxDepends on the batteries connected.13.5 kg
SYSR-1500L1500VA / 1200W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms maxDepends on the batteries connected.16.0 kg
SYSR-2000L2000VA / 1600W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms maxDepends on the batteries connected.18.6 kg
SYSR-3000L3000VA / 2400W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms maxDepends on the batteries connected.20.5 kg
SYSR-5000L5000VA / 4000W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms maxDepends on the batteries connected.30.8 kg
ModelsPower RatingInput Voltage RangeOutput Voltage RangeTransfer TimeCharging PeriodWeight
SYSR-600600VA / 360W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms max6-8 hours recover to 90% capacity4.5kg
SYSR-10001000VA / 800W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms max6-8 hours recover to 90% capacity9.0kg
SYSR-15001500VA / 1200W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms max6-8 hours recover to 90% capacity12.1kg
SYSR-20002000VA / 1600W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms max6-8 hours recover to 90% capacity22.5kg
SYSR-30003000VA / 2400W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms max6-8 hours recover to 90% capacity24.5kg
SYSR-50005000VA / 4000W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms max6-8 hours recover to 90% capacity30.0kg
SYSR-600L600VA / 360W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms maxDepends on the batteries connected.3.8kg
SYSR-1000L1000VA / 800W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms maxDepends on the batteries connected.6.0kg
SYSR-1500L1500VA / 1200W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms maxDepends on the batteries connected.8.1kg
SYSR-2000L2000VA / 1600W145 - 275 Vac200 - 240 VacTypical: 2-6ms, 10ms maxDepends on the batteries connected.17.8kg
ModelsPower RatingInput Voltage RangeOutput Voltage RangeTransfer TimeCharging PeriodWeight
SYS-12001200VA / 720W85-150Vac / 145-290Vac102-132Vac / 200-255VacTypical: 2-6ms, 10ms max4-6 hours recover to 90% capacity9.5kg
SYS-15001500VA / 900W85-150Vac / 145-290Vac102-132Vac / 200-255VacTypical: 2-6ms, 10ms max4-6 hours recover to 90% capacity11.5kg
SYS-20002000VA / 1200W85-150Vac / 175-275Vac102-132Vac / 198-242VacTypical: 2-6ms, 10ms max4-6 hours recover to 90% capacity14.7kg
SYS-30003000VA / 1800W85-150Vac / 175-275Vac102-132Vac / 198-242VacTypical: 2-6ms, 10ms max4-6 hours recover to 90% capacity20.0kg
ModelsPower RatingInput Voltage RangeOutput Voltage RangeTransfer TimeCharging PeriodWeight
SYS-525500VA / 300W90-132Vac / 175-265Vac90-132Vac / 175-265VacTypical: 2-6ms, 10ms max4-6 hours recover to 90% capacity3.5kg
SYS-525A500VA / 300W85-150Vac / 145-290Vac102-132Vac / 200-255VacTypical: 2-6ms, 10ms max4-6 hours recover to 90% capacity3.6kg
SYS-625600VA / 360W85-150Vac / 145-290Vac102-132Vac / 200-255VacTypical: 2-6ms, 10ms max4-6 hours recover to 90% capacity4.3kg
SYS-10001000VA / 500W85-150Vac / 145-290Vac102-132Vac / 200-255VacTypical: 2-6ms, 10ms max4-6 hours recover to 90% capacity4.8kg

SOETECK SY-T Series UPS, Online High-frequency UPS, 400kVA-2000kVA, Tower, PF1, True Double Conversion

The SOETECK SY-T Series UPS, Online High-frequency UPS, 400kVA-2000kVA, Tower, PF1, True Double Conversion offers unparalleled power protection for mission-critical systems. With a three-phase input/output design, 98.5% efficiency in ECO mode, and flexible battery configurations, it guarantees operational reliability....
Models
ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
N/A400kVA / 400kVA304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
N/A500kVA / 500kVA304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
N/A600kVA / 600kVA304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
N/A1000kVA / 1000kW304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
N/A1500kVA / 1500kW304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
N/A2000kVA / 2000kW304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out

SOETECK SY-T Series Online High-frequency UPS, 100-300kVA, Tower, PF1

The SOETECK SY-T Series Online High-frequency UPS, 100-300kVA, Tower, PF1 provides reliable, energy-efficient power protection for critical systems. Supporting three-phase input and output, it delivers a wide input voltage range of 110-300V and up to 98.5% efficiency in ECO mode. With modular, pluggable power modules,...
Models
ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
N/A100kVA / 100kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
N/A120kVA / 120kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
N/A180kVA / 180kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
N/A200kVA / 200kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
N/A240kVA / 240kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
N/A300kVA / 300kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out

SOETECK SY-T Series Online High-frequency UPS, 10-60kVA, Tower, PF1

The SOETECK SY-T Series Online High-frequency UPS, 10-60kVA, Tower, PF1 offers robust and efficient power protection for mission-critical systems. With true double-conversion technology, a power factor of 1.0, and three-phase input/output support, it ensures clean and reliable power delivery. Its wide input voltage ran...
Models
ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
N/A10kVA / 10kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out; 3 phase in, 1 phase out; 1 phase in, 1 phase out
N/A20kVA / 20kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out; 3 phase in, 1 phase out; 1 phase in, 1 phase out
N/A30kVA / 30kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase + N + PE
N/A40kVA / 40kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase + N + PE
N/A60kVA / 60kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH+N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase + N + PE

SOETECK SY-T Series Online High-frequency UPS, 6kVA/10kVA, Tower, PF1, True Double Conversion

The SOETECK SY-T Series Online High-frequency UPS, 6kVA/10kVA, Tower, PF1, True Double Conversion provides reliable and efficient power protection for critical systems. Supporting single-phase input and output, it delivers up to 94% efficiency in AC mode and features a wide input voltage range of 110V to 300V. With low...
Models
ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
N/A6kVA/6kW110~300VAC (± 3%) at 50% load; 176~300VAC (± 3%) at 100% loadNominal: 208/220/230/240 VAC94% (AC mode) ; 98.5% ( ECO mode) ; 92% ( Battery mode )1 phase in, 1 phase out
N/A10kVA/10kW110~300VAC (± 3%) at 50% load; 176~300VAC (± 3%) at 100% loadNominal: 208/220/230/240 VAC94% (AC mode) ; 98.5% ( ECO mode) ; 92% ( Battery mode )1 phase in, 1 phase out

SOETECK SY-T Series Online High-frequency UPS, 1kVA/2kVA/3kVA, Tower, PF1, True Double Conversion

The SOETECK SY-T Series Online High-frequency UPS, 1kVA/2kVA/3kVA, Tower, PF1, True Double Conversion is a compact, high-performance UPS solution designed for critical applications. Supporting single-phase input and output, it delivers clean and stable power with a power factor of 1.0. With up to 97% efficiency in ECO...
Models
ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
N/A1000VA / 1000W110~300 VAC(Based on load at 50%); 160~300 VAC (Based on load at 100%)Nominal: 200/208/220/230/240 VAC≧ 92% or ≧ 94% at full charged battery ( AC mode ) ; ≧ 96% at full charged battery ( ECO mode ) ; ≧ 86% or ≧ 91% ( Battery mode )1 phase + PE
N/A2000VA / 2000W110~300 VAC(Based on load at 50%); 160~300 VAC (Based on load at 100%)Nominal: 200/208/220/230/240 VAC≧ 92% or ≧ 94% at full charged battery ( AC mode ) ; ≧ 96% at full charged battery ( ECO mode ) ; ≧ 86% or ≧ 91% ( Battery mode )1 phase + PE
N/A3000VA / 3000W110~300 VAC(Based on load at 50%); 160~300 VAC (Based on load at 100%)Nominal: 200/208/220/230/240 VAC≧ 92% or ≧ 94% at full charged battery ( AC mode ) ; ≧ 96% at full charged battery ( ECO mode ) ; ≧ 86% or ≧ 91% ( Battery mode )1 phase + PE

SOETECK SY-T Series Winner Pro+ UPS, Online High-frequency UPS, 1kVA-10kVA, Tower Mount, PF0.9, True Double Conversion

The SOETECK SY-T Series Winner Pro+ UPS, Online High-frequency UPS, 1kVA-10kVA, Tower Mount, PF0.9, True Double Conversion is a versatile and energy-efficient power protection solution. With true double-conversion technology, a wide input voltage range of 110V to 300V, and high PF 0.9 output, it ensures clean and relia...
Models
ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
N/A1000VA / 900W60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%)Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase + PE
N/A2000VA / 1800W60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%)Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase + PE
N/A3000VA / 2700W60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%)Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase + PE
N/A6000VA / 5400W60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%)Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase + PE
N/A10000VA / 9000W60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%)Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase + PE
1 2 3