"(《世界人权宣言》) SOETECK SY-RT 系列 Winner Pro+ UPS,在线式高频 UPS 1kVA-10kVA 提供可靠的电源保护,具有高 PF0.9 和 真正的双重转换 技术。支持 机架和塔 在安装过程中,可实现 93% 效率 并确保 零传输时间.可扩展的电池选项和智能监控功能使其成为关键应用的理想选择。
UPS 结构 | 在线双重转换 |
输入电压 | 110/115/120/127VAC, 208/220/230/240VAC |
输出电压 | 110/115/120/127VAC, 208/220/230/240VAC |
功率因数 | ≥ 0.99 @ 100% load |
频率 | 46Hz ~ 54 Hz or 56Hz ~ 64 Hz |
效率 | 83 - 93% |
波形 | 纯正弦波 |
噪音 | Less than 50dBA @ 1 meter |
"(《世界人权宣言》) SOETECK SY-RT 系列 Winner Pro+ UPS,在线式高频 UPS 1kVA-10kVA delivers premium power protection with its 真正的双重转换 technology and high PF0.9 output power factor. Designed for critical applications, it ensures stable, clean, and continuous power, ideal for small to medium-sized IT systems and sensitive electronics.
Featuring an advanced microprocessor control system, this UPS supports both rack and tower installations, offering versatile deployment options. The system achieves excellent 92%-93% efficiency in AC mode, reducing energy consumption and operational costs. Its 零传输时间(0ms) from AC to battery mode guarantees uninterrupted power during grid failures.
With an adjustable charging current range of 1A-6A and extended runtime options via external battery packs, the SOETECK SY-RT Series Winner Pro+ offers scalable backup power solutions. The comprehensive 液晶显示屏 and intelligent monitoring interfaces, including RS232, USB, and optional SNMP, ensure real-time system status and remote management capabilities.
"(《世界人权宣言》) SOETECK SY-RT 系列 Winner Pro+ UPS,在线式高频 UPS 1kVA-10kVA provides advanced power protection with PF0.9 for improved load efficiency. Featuring 真正的双重转换 technology, 零传输时间和 93% 效率, it guarantees stable, clean power for sensitive applications. Flexible rack and tower installation options and scalable battery configurations with adjustable charging current (1A-6A) make it a reliable solution for IT systems, server rooms, and telecommunication environments.
型号 | 额定功率 | 输入电压范围 | 输出电压范围 | 效率 | 布线 |
---|---|---|---|---|---|
SYRTWinner Pro+1kVA | 1000VA / 900W | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | 88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode ) | 1 phase + PE |
SYRTWinner Pro+2kVA | 2000VA / 1800W | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | 88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode ) | 1 phase + PE |
SYRTWinner Pro+3kVA | 3000VA / 2700W | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | 88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode ) | 1 phase + PE |
SYRTWinner Pro+6kVA | 6000VA / 5400W | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | 88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode ) | 1 phase + PE |
SYRTWinner Pro+10kVA | 10000VA / 9000W | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | 88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode ) | 1 phase + PE |
容量 | 1000VA/900W ; 2000VA/1800W ; 3000VA/2700W ; 6000VA/5400W ; 10000VA/9000W |
Nominal voltage | 110/115/120/127VAC or 208/220/230/240VA ; 208/220/230/240VAC |
Input voltage range | 60-145 VAC or 120-300 VAC (Based on load at 50%) 90-145 VAC or 180-300 VAC (Based on load at 100%) ; 110-300 VAC (Based on load at 50%) 176-300 VAC (Based on load at 100%) |
Frequency range | 40Hz ~ 70 Hz / 46~54 Hz or 56~64 Hz |
Power factor | ≥ 0.99 @ 100% load |
Output voltage | 110/115/120/127VAC or 208/220/230/240VAC ; 208/220/230/240VAC |
Voltage regulation | ± 1% |
Frequency range (Synchronized range) | 47~ 53 Hz or 57 ~ 63 Hz / 46Hz ~ 54 Hz or 56Hz ~ 64 Hz |
Frequency range (Battery mode) | 50 Hz or 60Hz ± 0.5% / 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Current crest ratio | 3:1 |
Harmonic distortion | ≤ 3% THD (Linear Load); ≤ 6% THD (Nonlinear Load) / ≦ 3% THD(Linear Load);≦ 5% THD(Non-linear Load) |
Transfer Time AC mode to battery mode | 0 ms |
Transfer Time Inverter to bypass | 4 milliseconds (under standard conditions) / 0ms |
波形(电池模式) | Pure sinewave |
AC mode | 88%/89%/90%/92%/ 93% |
Battery mode | 83%/87%/88%/90%/91% |
Battery type | 12 V / 9 AH |
数字 | 2/3/4/6/16/20/16/20 |
典型充电时间 | Charge to 90% in 4 hours / 9 hours recover to 90% capacity |
充电电流(最大值) | 1.0A (maximum) ; 1A/2A (Adjustable) |
充电电压 | 27.4VDC ± 1% ; 41.0VDC ± 1% ; 54.7 VDC ±1% ; 82.1 VDC ±1% ; 218.4 VDC ± 1% ; 273VDC ± 1% ; 218.4 VDC ± 1% ; 273VDC ± 1% |
Battery type | Match multiple battery boxes according to actual applications |
数字 | 3/6/6/16 ~ 20 (Adjustable) |
充电电流(最大值) | 1.0A/2.0A/4.0A/6.0 A ; 1A/2A/4A/6A (Adjustable, 6A is only available for 16 pcs batteries) |
充电电压 | 41.0 VDC ±1% ; 82.1 VDC ±1% ; 82.1 VDC±1% ; 218.4 VDC ± 1%(Based on 16 pcs batteries) |
液晶显示 | Load size, battery capacity, mains mode, battery mode, bypass mode, fault indication |
Battery mode | 每 4 秒钟响一次 |
Low battery | Sounding every second |
超负荷 | 每秒响两次 |
故障 | 持续发声 |
长 * 宽 * 高(毫米) | 310 x 438 x 88 / 410 x 438 x 88 / 630 x 438 x 88 / UPS Unit: 500x438x88 [2U] Battery Pack: 668x438x88 [2U] / UPS Unit: 500x438x88 [2U] Battery Pack: 580x438x133 [3U] / UPS Unit: 500x438x133 [2U] Battery Pack: 580x438x133 [3U] |
Net weight (kg) | 12/14.1/19/29.3/UPS Unit:15 Battery pack:48/UPS Unit: 15 Battery Pack: 61/UPS Unit: 18 Battery Pack: 51/UPS Unit: 18 Battery Pack: 61 |
长 * 宽 * 高(毫米) | 310 x 438 x 88 / 410 x 438 x 88 / 410 x 438 x 88 / 500 x 438 x 88 [2U] / 580 x 438 x 133 [3U] |
Net weight (kg) | 9/12/14.2/15/18 |
Humidity | Relative humidity 20-90% and temperature 0-40 ° C (non condensing) / 0-95% RH @ 0-40°C (non-condensing) |
Noise level | Less than 50dB @ 1 Meter / Less than 55dBA @ 1 meter / Less than 58dBA @ 1 meter |
智能 RS-232 / USB | 支持 Windows® 2000/2003/XP/Vista/2008、Windows® 7/8/10、Linux 和 MAC |
可选的 SNMP | 通过 SNMP 管理器和网络浏览器进行电源管理 |
我们提供 24/7 全天候的客户支持,不仅仅是销售产品,还提供全面的帮助。
我们的专业团队随时准备提供报价、量身定制的咨询和产品选择方面的专家建议。
如果方便,请提供您的行业背景或具体应用,以及您感兴趣的产品和服务。这些信息将有助于我们为您提供更加个性化的解决方案和准确的报价。
为了给您提供更好的体验,我们使用 cookie 来分析流量和提供个性化内容。您可以选择接受 Cookie 或管理您的偏好。如需了解更多信息,请参阅我们的 Cookie 政策和隐私政策。