"(《世界人权宣言》) SOETECK ST-RT Series, Online High-Frequency UPS 10kVA-60kVA delivers true double-conversion power protection 与 3 Phase In / 3 Phase Out architecture, ensuring uninterrupted power for critical systems. With PF1 效率, 95.5% ECO mode, and flexible rack/tower-mounted installation, it is designed for reliable and energy-efficient performance in demanding environments.
无数据 |
"(《世界人权宣言》) SOETECK ST-RT Series, Online High-Frequency UPS 10kVA-60kVA offers advanced 3 Phase In / 3 Phase Out power protection with true double-conversion technology, ensuring reliable and clean power delivery for critical systems. With a robust DSP control system and output power factor of 1.0, this series guarantees high performance and full-rated capacity for connected loads.
Featuring a wide input voltage range of 190-520VAC, the UPS is adaptable to fluctuating grid conditions while maintaining stable output voltage. The advanced 50/60Hz frequency converter mode provides flexibility for diverse applications, and its 95.5% ECO Mode efficiency reduces operational costs by maximizing energy savings.
With flexible 机架式和塔式 designs, hot-swappable battery support, and optional parallel redundancy for enhanced reliability, the SOETECK ST-RT Series is ideal for data centers, industrial automation, and mission-critical IT equipment.
"(《世界人权宣言》) SOETECK ST-RT Series, Online High-Frequency UPS 10kVA-60kVA offers 3 Phase In / 3 Phase Out architecture with true double-conversion technology for superior power protection. With an output power factor of 1.0 and high overload capabilities (125% for 10 minutes 和 150% for 1 minute), it ensures consistent power delivery. Its flexible rack/tower-mounted design and advanced energy-saving modes (95.5% ECO efficiency) make it the ideal choice for mission-critical applications requiring reliability and efficiency.
型号 | Power Rating | 输入电压范围 | 输出电压范围 | 效率 | 布线 |
---|---|---|---|---|---|
不适用 | 10kVA/10kW | 190-520VAC ( 3-phase ) at 50% load; -305-478VAC ( 3-phase) at 100% load | 3 x 360/380/400/415 VAC (3PH+N) | 95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode ) | 3 phase in, 3 phase out |
不适用 | 15kVA/15kW | 190-520VAC ( 3-phase ) at 50% load; -305-478VAC ( 3-phase) at 100% load | 3 x 360/380/400/415 VAC (3PH+N) | 95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode ) | 3 phase in, 3 phase out |
不适用 | 20kVA/20kW | 190-520VAC ( 3-phase ) at 50% load; -305-478VAC ( 3-phase) at 100% load | 3 x 360/380/400/415 VAC (3PH+N) | 95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode ) | 3 phase in, 3 phase out |
不适用 | 30kVA/30kW | 190-520VAC ( 3-phase ) at 50% load; -305-478VAC ( 3-phase) at 100% load | 3 x 360/380/400/415 VAC (3PH+N) | 95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode ) | 3 phase in, 3 phase out |
不适用 | 40kVA/40kW | 190-520VAC ( 3-phase ) at 50% load; -305-478VAC ( 3-phase) at 100% load | 3 x 360/380/400/415 VAC (3PH+N) | 95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode ) | 3 phase in, 3 phase out |
不适用 | 60kVA/60kW | 190-520VAC ( 3-phase ) at 50% load; -305-478VAC ( 3-phase) at 100% load | 3 x 360/380/400/415 VAC (3PH+N) | 95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode ) | 3 phase in, 3 phase out |
容量 | 10kVA/10kW ; 15kVA/15kW ; 20kVA/20kW ; 30kVA/30kW ; 40kVA/40kW ; 60kVA/60kW |
Phase | Three in, three out |
Parallel Capacity | 4 max |
Rated Voltage | 3 x 380 VAC (3PH+N) |
Voltage Range | 190-520VAC (three-phase) @ 50% load, -305-478VAC (three-phase) @ 100% load |
Frequency Range | 46 ~ 54 Hz or 56 ~ 64Hz |
功率因数 | ≧ 0.99 100% load |
Rated Voltage | 3 x 360*/380/400/415 VAC (3PH+N) |
Output Accuracy (battery mode) | ± 1% |
Frequency Range (synchronous correction range) | 46 ~ 54Hz or 56 ~ 64Hz |
Frequency Range (battery mode) | 50Hz ± 0.1Hz or 60Hz ± 0.1Hz |
Current Peak Ratio | 3: 1 (maximum value) |
Harmonic Distortion | ≤ 1% THD (linear load) ≤ 3% THD (nonlinear load) |
Transfer Time( AC mode to battery mode) | Not have |
Transfer Time( Inverter to bypass) | Not have |
Waveform(battery mode) | Pure sine wave |
Overload(AC mode) | 100% -110% 60 minutes, 110% -125% 10 minutes, 125% -150% 1 minute,>150% immediate protection |
Overload(battery mode) | 100% -110% 60 minutes, 110% -125% 10 minutes, 125% -150% 1 minute,>150% immediate protection |
AC Mode | 95.5% |
ECO Mode | 98.5% |
Battery Mode | 94.5% |
Type | Match multiple battery boxes according to actual applications |
Numbers | 20 / 32 ~ 40 (Adjustable) |
Maximum Charging Current | 1A ~ 12A (Adjustable) / 1A ~ 16A (Adjustable) / 1A ~ 18A (Adjustable) |
Charging Voltage | ± 13.65 VDC x N (N=10) / ± 13.65 V x N ( N = 16 ~ 20 ) |
Size: Depth * Width * Height (mm) | 680 x 438 x 133 [3U] / 797 x 438 x 176 [4U] |
Net Weight (kg) | 27/30/32/40/45 |
Temperature and Humidity | 0-95% relative humidity (non condensing) and temperature 0-40 ℃ |
Noise | less than 62dB@1 m / less than 65dB@1 m / less than 70dB@1 m |
Intelligent RS-232/USB | Supports Windows® series, Linux and MAC |
Optional SNMP | Power management supports SNMP management and network management |