"(《世界人权宣言》) SOETECK SY-RT 系列,在线式高频 UPS 1kVA-3kVA 提供业界领先的 PF1 效率 和 真正的双重转换技术确保清洁、稳定的电力输送,同时 0ms 传输时间 用于关键设备。设计用于 机架式和塔式 配置,具有宽输入电压范围 (110-300VAC)和快速 4ms 逆变器至旁路 切换。通过 96% 在 ECO 模式下的效率 充电电流最高可调至 8A对于需要可靠电源保护的 IT 系统、服务器机房和敏感应用来说,它是一个理想的选择。
无数据 |
"(《世界人权宣言》) SOETECK SY-RT 系列,在线式高频 UPS 1kVA-3kVA delivers industry-leading power protection with a PF1 output power factor, maximizing usable power for connected loads. Featuring 真正的双重转换 technology, it ensures seamless, clean, and stable power for critical equipment, eliminating risks of power disruptions and fluctuations.
Designed for versatility, the UPS supports both 机架式和塔式 configurations, offering flexibility for IT infrastructure deployments. Its wide input voltage range of 110-300VAC adapts to unstable grid conditions, while advanced ECO mode improves efficiency to over 96%, reducing operational costs.
With an adjustable charging current (up to 8A) and hot-swappable batteries, the SOETECK SY-RT Series provides extended runtime options and simplified maintenance. Fast switching (4ms for Inverter to Bypass) and a comprehensive LCD display ensure continuous monitoring and reliable power protection for servers, networking, and sensitive electronics.
"(《世界人权宣言》) SOETECK SY-RT 系列,在线式高频 UPS 1kVA-3kVA is engineered for critical power protection with PF1 efficiency and true double conversion technology. Featuring zero transfer time for AC to battery mode and a fast 4ms transfer for inverter to bypass, it ensures uninterrupted power delivery. Its flexible rack/tower-mounted design, hot-swappable batteries, and adjustable charging current (up to 8A) make it an ideal choice for IT systems, small data centers, and sensitive electronics.
型号 | Power Rating | 输入电压范围 | 输出电压范围 | 效率 | 布线 |
---|---|---|---|---|---|
不适用 | 1000VA / 1000W | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | ≧ 89% or ≧ 91% ( AC mode ) ; ≧ 96% ( ECO mode ) ; ≧ 88% or ≧ 90% ( Battery mode ) | 1 phase + PE |
不适用 | 1500VA / 1500W | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | ≧ 89% or ≧ 91% ( AC mode ) ; ≧ 96% ( ECO mode ) ; ≧ 88% or ≧ 90% ( Battery mode ) | 1 phase + PE |
不适用 | 2000VA / 2000W | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | ≧ 89% or ≧ 91% ( AC mode ) ; ≧ 96% ( ECO mode ) ; ≧ 88% or ≧ 90% ( Battery mode ) | 1 phase + PE |
不适用 | 3000VA / 3000W | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | ≧ 89% or ≧ 91% ( AC mode ) ; ≧ 96% ( ECO mode ) ; ≧ 88% or ≧ 90% ( Battery mode ) | 1 phase + PE |
容量 | 1000VA/1000W ; 1500VA/1500W ; 2000VA/2000W ; 3000VA/3000W |
额定电压 | 100/110/115/120/127 VAC or 200/208/220/230/240 VAC |
Voltage Range | 55-150 VAC ± 5% or 110-300 VAC ± 5% @ 50% load 80-150 VAC ± 5% or 160-300 VAC ± 5% @ 100% load |
Frequency Range | 40Hz ~ 70 Hz |
功率因数 | ≧ 0.99 @ nominal voltage (100% load) |
Harmonic Distortion(THDi) | ≦ 5% @ nominal input voltage |
Output Voltage | 100*/110*/115*/120/127 VAC or 200*/208*/220/230/240 VAC |
AC Voltage Regulation (Batt. Mode) | ± 1% |
Frequency Range (Synchronized range) | 57 ~ 63 Hz or 47 ~ 53 Hz |
Frequency Range (Battery mode) | 60Hz ± 0.1Hz or 50 Hz ± 0.1Hz |
Current Crest Ratio | 3:1 (max.) |
Harmonic Distortion | ≦2 % THD (Linear Load) ; ≦ 4 % THD (Non-linear Load) |
Transfer Time AC Mode to Batt. Mode | Zero |
Transfer Time Inverter to Bypass | 4 ms (Typical) |
Waveform (battery mode) | Pure Sinewave |
AC Mode | ≧89% @ full charged battery / ≧91% @ full charged battery |
ECO Mode | ≧96% @ full charged battery |
Battery Mode | ≧88% / ≧90% |
Battery type | 12 V / 9 Ah ; 12 V / 7 Ah |
Numbers | 2/3/3/4/6/6 |
Typical recharge time | 3 hours recover to 95% capacity for internal battery@ 2A charging current |
Charging Current | 100/110/115/120 /127 VAC models: default 2A, max. 8A adjustable 200/208/220/230/240 VAC models: default 2A, max. 12A adjustable ; Default: 2A, Max: 8A adjustable |
Charging Voltage | 27.4 VDC ± 1% / 41.1 VDC ± 1% / 41.1 VDC ± 1% / 54.8 VDC ±1% / 82.1 VDC ±1% / 82.1 VDC ±1% |
LCD | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Battery mode | Sounding every 5 seconds |
Low battery | Sounding every 2 second |
Overload | Sounding every second |
Fault | Continuously sounding |
Dimension, D x W x H(mm) | 410 x 438 x 88 / 410 x 438 x 88 / 510 x 438 x 88 / 630 x 438 x 88 / 630 x 438 x 88 |
Net Weight (without battery) (kgs) | 6.6/7.8/8.1/9.4/10.6/12.4 |
Net Weight (w/built-int battery) (kgs) | 11.6/14.1/15.5/19.5/23.3/27.5 |
Humidity | 20-90 % RH @ 0- 40°C (non-condensing) |
Noise level | Less than 50dB @ 1 Meter |
Altitude | 10% de-rating for over 1000m (The altitude should not exceed 3000m) |
Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC |
Optional SNMP | Power management from SNMP manager and web browser |
EMC/safety | (EMC 1-1.5K: EN62040-2 C1, 2K-3K EN62040-2 C2) for CE models |