"(《世界人权宣言》) SOETECK SY-RT 系列,在线式高频 UPS 1kVA-3kVA 提供业界领先的 PF1 效率 和 真正的双重转换技术确保清洁、稳定的电力输送,同时 0ms 传输时间 用于关键设备。设计用于 机架式和塔式 配置,具有宽输入电压范围 (110-300VAC)和快速 4ms 逆变器至旁路 切换。通过 96% 在 ECO 模式下的效率 充电电流最高可调至 8A对于需要可靠电源保护的 IT 系统、服务器机房和敏感应用来说,它是一个理想的选择。
UPS 结构 | 在线双重转换 |
输入电压 | 100/110/115/120/127VAC, 208/220/230/240VAC |
输出电压 | 100/110/115/120/127VAC, 208/220/230/240VAC |
功率因数 | ≥ 0.99 @ 100% load |
频率 | 57 ~ 63 Hz or 47 ~ 53 Hz |
效率 | ≥ 88 - 96% |
波形 | 纯正弦波 |
噪音 | Less than 50dBA @ 1 meter |
"(《世界人权宣言》) SOETECK SY-RT 系列,在线式高频 UPS 1kVA-3kVA delivers industry-leading power protection with a PF1 输出功率因数, maximizing usable power for connected loads. Featuring 真正的双重转换 technology, it ensures seamless, clean, and stable power for critical equipment, eliminating risks of power disruptions and fluctuations.
Designed for versatility, the UPS supports both 机架式和塔式 configurations, offering flexibility for IT infrastructure deployments. Its wide input voltage range of 110-300VAC adapts to unstable grid conditions, while advanced ECO mode improves efficiency to over 96%, reducing operational costs.
With an adjustable charging current (up to 8A) and hot-swappable batteries, the SOETECK SY-RT Series provides extended runtime options and simplified maintenance. Fast switching (4ms for Inverter to Bypass) and a comprehensive LCD display ensure continuous monitoring and reliable power protection for servers, networking, and sensitive electronics.
"(《世界人权宣言》) SOETECK SY-RT 系列,在线式高频 UPS 1kVA-3kVA is engineered for critical power protection with PF1 efficiency and true double conversion technology. Featuring zero transfer time for AC to battery mode and a fast 4ms transfer for inverter to bypass, it ensures uninterrupted power delivery. Its flexible 机架式/塔式 design, hot-swappable batteries, and adjustable charging current (up to 8A) make it an ideal choice for IT systems, small data centers, and sensitive electronics.
型号 | 额定功率 | 输入电压范围 | 输出电压范围 | 效率 | 布线 |
---|---|---|---|---|---|
SYRT1K | 1000VA / 1000W | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | ≧ 89% or ≧ 91% ( AC mode ) ; ≧ 96% ( ECO mode ) ; ≧ 88% or ≧ 90% ( Battery mode ) | 1 phase + PE |
SYRT1.5K | 1500VA / 1500W | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | ≧ 89% or ≧ 91% ( AC mode ) ; ≧ 96% ( ECO mode ) ; ≧ 88% or ≧ 90% ( Battery mode ) | 1 phase + PE |
SYRT2K | 2000VA / 2000W | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | ≧ 89% or ≧ 91% ( AC mode ) ; ≧ 96% ( ECO mode ) ; ≧ 88% or ≧ 90% ( Battery mode ) | 1 phase + PE |
SYRT3K | 3000VA / 3000W | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | ≧ 89% or ≧ 91% ( AC mode ) ; ≧ 96% ( ECO mode ) ; ≧ 88% or ≧ 90% ( Battery mode ) | 1 phase + PE |
容量 | 1000VA/1000W ; 1500VA/1500W ; 2000VA/2000W ; 3000VA/3000W |
额定电压 | 100/110/115/120/127 VAC or 200/208/220/230/240 VAC |
电压范围 | 55-150 VAC ± 5% or 110-300 VAC ± 5% @ 50% load 80-150 VAC ± 5% or 160-300 VAC ± 5% @ 100% load |
频率范围 | 40Hz ~ 70 Hz |
功率因数 | ≧ 0.99 @ nominal voltage (100% load) |
Harmonic Distortion(THDi) | ≦ 5% @ nominal input voltage |
输出电压 | 100*/110*/115*/120/127 VAC or 200*/208*/220/230/240 VAC |
AC Voltage Regulation (Batt. Mode) | ± 1% |
Frequency Range (Synchronized range) | 57 ~ 63 Hz or 47 ~ 53 Hz |
Frequency Range (Battery mode) | 60Hz ± 0.1Hz or 50 Hz ± 0.1Hz |
当前峰值比 | 3:1(最大值) |
谐波失真 | ≦2 % THD (Linear Load) ; ≦ 4 % THD (Non-linear Load) |
Transfer Time AC Mode to Batt. Mode | 零 |
Transfer Time Inverter to Bypass | 4 ms (Typical) |
波形(电池模式) | 纯正弦波 |
交流模式 | ≧89% @ full charged battery / ≧91% @ full charged battery |
经济模式 | ≧96% @ full charged battery |
电池模式 | ≧88% / ≧90% |
Battery type | 12 V / 9 Ah ; 12 V / 7 Ah |
数字 | 2/3/3/4/6/6 |
Typical recharge time | 3 hours recover to 95% capacity for internal battery@ 2A charging current |
Charging Current | 100/110/115/120 /127 VAC models: default 2A, max. 8A adjustable 200/208/220/230/240 VAC models: default 2A, max. 12A adjustable ; Default: 2A, Max: 8A adjustable |
充电电压 | 27.4 VDC ± 1% / 41.1 VDC ± 1% / 41.1 VDC ± 1% / 54.8 VDC ±1% / 82.1 VDC ±1% / 82.1 VDC ±1% |
液晶显示 | UPS 状态、负载水平、电池水平、输入/输出电压、放电计时器和故障条件 |
Battery mode | Sounding every 5 seconds |
Low battery | Sounding every 2 second |
超负荷 | Sounding every second |
故障 | 持续发声 |
Dimension, D x W x H(mm) | 410 x 438 x 88 / 410 x 438 x 88 / 510 x 438 x 88 / 630 x 438 x 88 / 630 x 438 x 88 |
Net Weight (without battery) (kgs) | 6.6/7.8/8.1/9.4/10.6/12.4 |
Net Weight (w/built-int battery) (kgs) | 11.6/14.1/15.5/19.5/23.3/27.5 |
Humidity | 20-90 % 相对湿度 @ 0-40°C(无冷凝) |
Noise level | Less than 50dB @ 1 Meter |
Altitude | 10% de-rating for over 1000m (The altitude should not exceed 3000m) |
智能 RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC |
可选的 SNMP | 通过 SNMP 管理器和网络浏览器进行电源管理 |
EMC/safety | (EMC 1-1.5K: EN62040-2 C1, 2K-3K EN62040-2 C2) for CE models |
我们提供 24/7 全天候的客户支持,不仅仅是销售产品,还提供全面的帮助。
我们的专业团队随时准备提供报价、量身定制的咨询和产品选择方面的专家建议。
如果方便,请提供您的行业背景或具体应用,以及您感兴趣的产品和服务。这些信息将有助于我们为您提供更加个性化的解决方案和准确的报价。
为了给您提供更好的体验,我们使用 cookie 来分析流量和提供个性化内容。您可以选择接受 Cookie 或管理您的偏好。如需了解更多信息,请参阅我们的 Cookie 政策和隐私政策。