Models | Power Rating | Input Voltage Range | Output Voltage Range | Efficiency | Wiring |
---|---|---|---|---|---|
N/A | 150kva | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 95.5% ( Normal mode ) ; 95% ( Battery mode ) | 3 phase + N + PE |
N/A | 200kVA | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 95.5% ( Normal mode ) ; 95% ( Battery mode ) | 3 phase + N + PE |
Models | Power Rating | Input Voltage Range | Output Voltage Range | Efficiency | Wiring |
---|---|---|---|---|---|
N/A | 20kVA(10x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | ≥ 95% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 94.5% ( Battery mode ) | 3 phase + N + PE |
N/A | 30kVA(10x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | ≥ 95% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 94.5% ( Battery mode ) | 3 phase + N + PE |
N/A | 40kVA(10x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | ≥ 95% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 94.5% ( Battery mode ) | 3 phase + N + PE |
N/A | 60kVA(10x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | ≥ 95% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 94.5% ( Battery mode ) | 3 phase + N + PE |
N/A | 30kVA(15x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | ≥ 95% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 94.5% ( Battery mode ) | 3 phase + N + PE |
N/A | 45kVA(15x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | ≥ 95% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 94.5% ( Battery mode ) | 3 phase + N + PE |
N/A | 90kVA(15x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | ≥ 95% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 94.5% ( Battery mode ) | 3 phase + N + PE |
Models | Power Rating | Input Voltage Range | Output Voltage Range | Efficiency | Wiring |
---|---|---|---|---|---|
N/A | 5kVA | 277~478VAC (Line Voltage), 147~277VAC (Line Voltage) at full load, linearly derating from 100% to 50% load | 220/230/240VAC | ≥ 94.5% ( Normal mode ) | 3 phase + N + PE |
N/A | 10kVA | 277~478VAC (Line Voltage), 147~277VAC (Line Voltage) at full load, linearly derating from 100% to 50% load | 220/230/240VAC | ≥ 94.5% ( Normal mode ) | 3 phase + N + PE |
N/A | 15kVA | 277~478VAC (Line Voltage), 147~277VAC (Line Voltage) at full load, linearly derating from 100% to 50% load | 220/230/240VAC | ≥ 94.5% ( Normal mode ) | 3 phase + N + PE |
N/A | 20kVA | 277~478VAC (Line Voltage), 147~277VAC (Line Voltage) at full load, linearly derating from 100% to 50% load | 220/230/240VAC | ≥ 94.5% ( Normal mode ) | 3 phase + N + PE |
Models | Power Rating | Input Voltage Range | Output Voltage Range | Efficiency | Wiring |
---|---|---|---|---|---|
N/A | 20kVA | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 92% ( Normal mode ) ; 95% ( ECO mode ) ; 92% ( Battery mode ) | 3 phase + N + PE |
N/A | 40kVA | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 92% ( Normal mode ) ; 95% ( ECO mode ) ; 92% ( Battery mode ) | 3 phase + N + PE |
N/A | 60kVA | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 92% ( Normal mode ) ; 95% ( ECO mode ) ; 92% ( Battery mode ) | 3 phase + N + PE |
Models | Power Rating | Input Voltage Range | Output Voltage Range | Efficiency | Wiring |
---|---|---|---|---|---|
N/A | 400kVA | 138~485VAC (138~323VAC linear derating, 324~485VAC no derating) | 380/400/415VAC ( Line Voltage ) | ≥ 96% | 3 phase + N + PE |
N/A | 500kVA | 138~485VAC (138~323VAC linear derating, 324~485VAC no derating) | 380/400/415VAC ( Line Voltage ) | ≥ 96% | 3 phase + N + PE |
N/A | 600kVA | 138~485VAC (138~323VAC linear derating, 324~485VAC no derating) | 380/400/415VAC ( Line Voltage ) | ≥ 96% | 3 phase + N + PE |
N/A | 800kVA | 138~485VAC (138~323VAC linear derating, 324~485VAC no derating) | 380/400/415VAC ( Line Voltage ) | ≥ 96% | 3 phase + N + PE |
N/A | 1000kVA | 138~485VAC (138~323VAC linear derating, 324~485VAC no derating) | 380/400/415VAC ( Line Voltage ) | ≥ 96% | 3 phase + N + PE |
N/A | 1100kVA | 138~485VAC (138~323VAC linear derating, 324~485VAC no derating) | 380/400/415VAC ( Line Voltage ) | ≥ 96% | 3 phase + N + PE |
N/A | 1200kVA | 138~485VAC (138~323VAC linear derating, 324~485VAC no derating) | 380/400/415VAC ( Line Voltage ) | ≥ 96% | 3 phase + N + PE |
N/A | 1300kVA | 138~485VAC (138~323VAC linear derating, 324~485VAC no derating) | 380/400/415VAC ( Line Voltage ) | ≥ 96% | 3 phase + N + PE |
N/A | 1400kVA | 138~485VAC (138~323VAC linear derating, 324~485VAC no derating) | 380/400/415VAC ( Line Voltage ) | ≥ 96% | 3 phase + N + PE |
Models | Power Rating | Input Voltage Range | Output Voltage Range | Efficiency | Wiring |
---|---|---|---|---|---|
N/A | 600kVA | 323~478VAC (Line Voltage), full load, at 30~40 ℃; 323~138VAC (Line Voltage), linearly derating load from 100% to 30%, at 30~40 ℃ | 380/400/415VAC ( Line Voltage ) | 96% ( Normal mode ) ; 95% ( Battery mode ) | 3 phase + N + PE |
Models | Power Rating | Input Voltage Range | Output Voltage Range | Efficiency | Wiring |
---|---|---|---|---|---|
N/A | 600kVA | 323~478VAC (Line Voltage), full load, at 30~40 ℃; 323~138VAC (Line Voltage), linearly derating load from 100% to 30%, at 30~40 ℃ | 380/400/415VAC ( Line Voltage ) | 97% ( Normal mode ) ; 96% ( Battery mode ) | 3 phase + N + PE |
Models | Power Rating | Input Voltage Range | Output Voltage Range | Efficiency | Wiring |
---|---|---|---|---|---|
N/A | 80kVA(40x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 96% ( Normal mode ) ; 96% ( Battery mode ) | 3 phase + N + PE |
N/A | 160kVA(40x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 96% ( Normal mode ) ; 96% ( Battery mode ) | 3 phase + N + PE |
N/A | 240kVA(40x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 96% ( Normal mode ) ; 96% ( Battery mode ) | 3 phase + N + PE |
N/A | 100kVA(50x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 96% ( Normal mode ) ; 96% ( Battery mode ) | 3 phase + N + PE |
N/A | 200kVA(50x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 96% ( Normal mode ) ; 96% ( Battery mode ) | 3 phase + N + PE |
N/A | 300kVA(50x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 96% ( Normal mode ) ; 96% ( Battery mode ) | 3 phase + N + PE |
N/A | 400kVA(50x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 96% ( Normal mode ) ; 96% ( Battery mode ) | 3 phase + N + PE |
N/A | 500kVA(50x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 96% ( Normal mode ) ; 96% ( Battery mode ) | 3 phase + N + PE |
N/A | 600kVA(50x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 96% ( Normal mode ) ; 96% ( Battery mode ) | 3 phase + N + PE |
Models | Power Rating | Input Voltage Range | Output Voltage Range | Efficiency | Wiring |
---|---|---|---|---|---|
N/A | 150kVA (25x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 95% ( Normal mode ) ; 95% ( Battery mode ) | 3 phase in, 3 phase out |
N/A | 250kVA(25x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 95% ( Normal mode ) ; 95% ( Battery mode ) | 3 phase in, 3 phase out |
N/A | 120kVA(30x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 95% ( Normal mode ) ; 95% ( Battery mode ) | 3 phase in, 3 phase out |
N/A | 180kVA(30x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 95% ( Normal mode ) ; 95% ( Battery mode ) | 3 phase in, 3 phase out |
N/A | 300kVA(30x) | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 95% ( Normal mode ) ; 95% ( Battery mode ) | 3 phase in, 3 phase out |
Models | Power Rating | Input Voltage Range | Output Voltage Range | Efficiency | Wiring |
---|---|---|---|---|---|
N/A | 60kVA | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 95% ( Normal mode ) ; ≥ 99% ( ECO mode ) | 3 phase + N + PE |
N/A | 120kVA | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 95% ( Normal mode ) ; ≥ 99% ( ECO mode ) | 3 phase + N + PE |
N/A | 200kVA | 304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40% | 380/400/415VAC ( Line Voltage ) | 95% ( Normal mode ) ; ≥ 99% ( ECO mode ) | 3 phase + N + PE |
© 2024 SOETECK, Inc. All rights reserved
© 2024 SOETECK, Inc. All rights reserved