The SOETECK ST-RT RT Series, Online High-frequency UPS 6kVA/10kVA offers PF1 power factor, true double conversion technology, and flexible rack/tower-mounted installation. With a wide input voltage range (110-300VAC), 98.5% efficiency in ECO mode, and zero transfer time for AC to Battery Mode, it delivers reliable and efficient power protection for critical applications.
No data available |
The SOETECK ST-RT RT Series, Online High-frequency UPS 6kVA/10kVA provides exceptional power protection with a PF1 output power factor and true double-conversion technology, ensuring clean, continuous, and reliable power for critical loads. Designed for flexibility, it supports both rack-mounted and tower-mounted installations, making it ideal for diverse environments.
With a wide input voltage range of 110-300VAC, this UPS adapts to unstable power grids while maintaining stable output voltage. Its advanced DSP control technology guarantees high performance, achieving AC Mode efficiency up to 94% and ECO Mode efficiency of 98.5%, optimizing energy savings and operational costs.
The SOETECK ST-RT RT Series also features fast transfer times, including zero transfer for AC to Battery Mode and efficient overload handling for Inverter to Bypass scenarios. Equipped with intelligent battery management and adjustable charging current, it ensures long battery life and quick recovery, making it an ideal solution for servers, network equipment, and sensitive electronics.
The SOETECK ST-RT RT Series, Online High-frequency UPS 6kVA/10kVA is designed for critical power protection with PF1 efficiency and true double-conversion technology. Featuring zero transfer time for AC to Battery Mode and fast switching for Inverter to Bypass, it ensures reliable performance under all conditions. Its flexible rack/tower-mounted design, intelligent battery management, and high efficiency (up to 98.5% in ECO mode) make it ideal for demanding IT systems, data centers, and sensitive applications.
Models | Power Rating | Input Voltage Range | Output Voltage Range | Efficiency | Wiring |
---|---|---|---|---|---|
N/A | 6000VA / 6000W | 110~300VAC (± 3%) at 50% load; 176~300VAC (± 3%) at 100% load | Nominal: 208/220/230/240 VAC | 94% (AC mode) ; 98.5% ( ECO mode) ; 92% ( Battery mode ) | 1 phase in, 1 phase out |
N/A | 10000VA / 10000W | 110~300VAC (± 3%) at 50% load; 176~300VAC (± 3%) at 100% load | Nominal: 208/220/230/240 VAC | 94% (AC mode) ; 98.5% ( ECO mode) ; 92% ( Battery mode ) | 1 phase in, 1 phase out |
Capacity | 6000VA/6000W / 10000VA/10000W |
Nominal Voltage | 208/220/230/240 VAC |
Voltage Range | 110~300VAC ± 3 % at 50% load / 176~300VAC ± 3 % at 100% load |
Frequency Range | 46~54 Hz ◎ 50Hz / 56~64 Hz ◎ 60Hz |
Power Factor | ≧ 0.99 @ full load |
THDi | < 4% @100% Load, < 6% @50% Load |
Output Voltage | 208*/220/230/240 VAC ; 208*/220/230/240 VAC |
AC Voltage Regulation | ± 1% |
Frequency Range (synchronized range) | 46~54 Hz ◎ 50Hz / 56~64 Hz ◎ 60Hz |
Frequency Range (battery mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Current Crest Ratio | 3:1 (max.) |
Harmonic Distortion | ≦1% THD (Linear Load), ≦4% THD (Non-linear Load) |
Transfer Time (AC mode to battery mode) | Zero |
Transfer Time (inverter to bypass) | Zero |
Waveform (battery mode) | Pure Sinewave |
Overload (AC mode) | 100%~110%: 10min、110%~130%: 1min、>130% : 1sec |
Overload (battery mode) | 100%~110%: 30sec、110%~130%: 10sec、>130% : 1sec |
AC Mode | 94% / 94% |
ECO Mode | 98.5% / 98.5% |
Battery Mode | 92% / 92% |
Battery Type | 12 V / 7 Ah ; 12 V / 9 Ah |
Battery Numbers | 16 / 20 / 16 / 20 |
Typical Recharge Time | 9 hours recover to 90% capacity |
Charging Current (max.) | 1.0 A |
Charging Voltage | 218.4 VDC ± 1% / 273 VDC ± 1% / 218.4 VDC ± 1% / 273 VDC ± 1% |
Battery Type | Depending on applications |
Numbers | 16-20 |
Charging Current (max.) | 4.0 A |
Charging Voltage | (13.65VDC x battery number) ± 1% |
LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every seconds |
Overload | Sounding twice every second |
Fault | Continuously sounding |
D * W * H (mm) | UPS Unit: 610 x 438 x 88 [2U] Battery Pack:715 x 438 x 88 [2U] ; UPS Unit: 610 x 438 x 88 [2U] Battery Pack:600 x 438 x 133 [3U] ; UPS Unit: 610 x 438 x 88 [2U] Battery Pack: 715 x 438 x 88 [2U] ; UPS Unit: 610 x 438 x 88 [2U] Battery Pack:600 x 438 x 133 [3U] |
Net Weight (kg) | UPS Unit: 17 Battery Pack: 48 ; UPS Unit: 17 Battery Pack: 57 ; UPS Unit: 20 Battery Pack: 53 ; UPS Unit: 20 Battery Pack: 63 |
D * W * H (mm) | 610 x 438 x 88 [2U] ; 610 x 438 x 88 [2U] |
Net Weight (kg) | 17/20 |
Operating Humidity | 20-90 % RH @ 0- 40°C (non-condensing) |
Noise Level | Less than 55dB @1Meter |
Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC |
Optional SNMP | Power management from SNMP manager and web browser |
We offer 24/7 customer support—not just to sell products, but to provide comprehensive assistance.
Our dedicated team is always ready to help with quotes, tailored consultations, and expert advice on product selection.
If convenient, please share your industry background or specific application, along with the products and services you’re interested in.This information will help us provide you with a more personalized solution and accurate quote.
We value every customer’s voice and look forward to discussing how we can provide the best solutions for your business.
© 2024 SOETECK, Inc. All rights reserved
© 2024 SOETECK, Inc. All rights reserved