Unidade de distribuição de refrigerante Soeteck AICoolit™ Room CDU
O Unidade de distribuição de refrigerante Soeteck AICoolit™ Room CDU is a room-level liquid cooling core device for medium-to-large data centers, HPC and AI centers, supporting over 100 liquid-cooled cabinets and high-computing scenarios with reliable N+1 redundancy and leakage monitoring, 800-2000kW heat exchange capacity, and intelligent O&M via Modbus/BACnet protocols.
| Capacidade de arrefecimento | 800/1000/1350/2000 kW |
| Caudal de entrada | 69.04-173.73 m³/h |
| Caudal de saída | 72.84-190.78 m³/h |
| Potência nominal | 15.5/18.5/22.5/33.0 kW |
| Tipo de fluido | Água / 25% EG |
| L*D*H | 980*1480*2000 mm |
| Peso | 800/1000/1200/1500 kg |
Visão geral do produto
Coolant Distribution Units are core components of liquid cooling solutions for data centers. The Soeteck AICoolit™ Room CDU Coolant Distribution Unit is a room-level liquid cooling core device tailored for medium-to-large liquid-cooled data centers, HPC clusterse AI intelligent computing centers. It is specifically designed for large-scale deployments with over 100 liquid-cooled cabinets, seamlessly adapting to high-computing-demand scenarios such as HPC scientific computing (including meteorological simulation and gene sequencing) and AI large model training.
Boasting reliable performance, the Coolant Distribution Unit features an N+1 redundancy design, multi-stage filtratione independent leakage monitoring to ensure uninterrupted cooling even during maintenance or unexpected faults. Its heat exchange capacity ranges from 800kW para 2000kW, covering a wide performance spectrum to meet the cooling needs of liquid cooling systems of different scales.
For operational efficiency, this CDU apoios online water quality monitoring and integrates remote communication protocols including Modbus and BACnet, enabling data center operators to achieve flexible, efficient operation and maintenance as well as intelligent centralized management.
Caraterísticas
High Cooling Capacity
- Offers a robust cooling capacity range of 200kW-2000kW, which is essential for efficiently managing the heat generated by large-scale, high-power computing equipment in data centers, HPC clusters, and intelligent computing centers. This ensures that servers and other hardware can operate within optimal temperature ranges, preventing overheating and potential performance degradation.
Superior System Reliability
- Employs an N + 1 redundancy design, meaning there is an extra unit available to take over in case of a component failure, ensuring uninterrupted cooling supply.
- Equipped with multiple filters to maintain the cleanliness of the coolant, preventing debris from causing blockages or damage to the system.
- Features an independent leak detection system that can promptly identify any coolant leaks, allowing for timely intervention to prevent system failures and minimize potential damage to equipment.
Convenient Online Maintenance
- Enables real-time online water quality detection, allowing administrators to monitor the condition of the coolant continuously. This helps in maintaining the coolant at an optimal state for heat transfer efficiency.
- Supports online replacement of coolant, which means the system can be serviced and the coolant refreshed without shutting down the entire unit, reducing downtime and ensuring the system operates at peak performance at all times.
Advanced Remote Management
- Integrates industry-standard communication protocols such as Modbus e BACnet, enabling seamless integration with existing building management systems.
- Facilitates remote data monitoring, allowing operators to keep track of critical parameters like temperature, pressure, and flow rate from a centralized location.
- Provides fault early warning capabilities, sending alerts when potential issues are detected, enabling proactive maintenance and reducing the risk of unexpected system outages.
Aplicações
- Medium-to-large-sized liquid-cooled data centers
- HPC (High-Performance Computing) clusters
- Intelligent computing centers for AI model training
Modelos
O Unidade de distribuição de refrigerante Soeteck Room CDU is available in multiple models to cater to different cooling requirements. The SY-CDU-RM-800 oferece uma capacidade de permuta de calor de 800kW, com um caudal de água de circulação do lado primário de 69.04 m³/h e uma potência nominal de 15,5 kW, making it suitable for moderately sized installations. The SY-CDU-RM-1000 model steps up with a 1000kW heat exchange capacity, a primary-side flow rate of 86.31 m³/h, e uma potência nominal de 18,5 kW, ideal for larger setups with increased heat loads. For the most demanding applications, the SY-CDU-RM-1350 model provides a substantial 1350kW heat exchange capacity, a primary-side flow rate of 116.501 m³/h, e uma potência nominal de 22,5 kW. O SY-CDU-RM-2000 model delivers top-tier performance with a 2000kW heat exchange capacity, a primary-side circulating water flow rate of 173.73 m³/h, e uma potência nominal de 33kW, tailored for ultra-large-scale data centers and high-density computing clusters with extreme heat dissipation needs. All models share common design principles in terms of reliability features like redundancy and leak detection, while differing in key performance parameters to offer flexibility in meeting various data center and computing cluster needs.
| Modelos | Capacidade de arrefecimento | Caudal de circulação | Potência nominal | Tipo de fluido | Contagem de bombas | Largura | Profundidade | Altura | Peso aproximado |
|---|---|---|---|---|---|---|---|---|---|
| SY-CDU-RM-800 | 800kW | 69.04/72.84 m³/h | 15,5 kW | Água / 25% EG | 2 | 980 mm | 1480mm | 2000mm | 850 kg |
| SY-CDU-RM-1000 | 1000kW | 86.31/91.05 m³/h | 18,5 kW | Água / 25% EG | 3 | 980 mm | 1480mm | 2000mm | 1000kg |
| SY-CDU-RM-1350 | 1350kW | 116.50/122.92 m³/h | 22,5 kW | Água / 25% EG | 3 | 980 mm | 1480mm | 2000mm | 1200kg |
| SY-CDU-RM-2000 | 2000kW | 173.73/190.78 m³/h | 33.0kW | Água / 25% EG | 3 | 980 mm | 1480mm | 2000mm | 1500kg |