|
Liquid Cooling Data Center
Prefabricated AI Infrastructure

Liquid Cooling Data Center

Delivered Anywhere.

Liquid Cooling has been the next-gen thermal management solution for data centers in the AI era. Soeteck AICoolit™ integrates Direct-to-Chip or Immersion cooling into ISO standard containers, enabling 100kW per rack density. Bypass lengthy construction cycles and get your compute cluster operational in weeks.

View ModelsGet Whitepaper
Engineering validated for
NVIDIA HGXINTEL GaudiAMD Instinct
100kW
Max Rack Density
1.15
Extreme pue
4Weeks
Typical lead time
IP65
Industrial Rating
The Competitive Edge

Why Liquid +Container?

In the AI boom, traditional infrastructure is the bottleneck. AICoolit fuses "Container Flexibility" with "Liquid Cooling Density," offering a superior third option.
VS. Traditional Air-Cooled Containers
Standard air-cooled containers are limited by airflow physics, capping rack density at 10-15kW—insufficient for NVIDIA H100 clusters.
Density Breakthrough
Liquid cooling shatters thermal limits, enabling 100kW+ per rack in a standard ISO footprint.
Environmental Resilience
Fully sealed liquid loop design. Immune to dust, humidity, or 50℃ ambient heat.
VS. Brick-and-Mortar Data Centers
Traditional builds face zoning issues, slow permits, and 12-24 month timelines, failing to keep pace with AI business expansion.
Rapid Time-to-Market
Factory prefabricated. Just connect power & water on-site. Compress delivery from "Years" to "Weeks".
Scalable CAPEX
No massive upfront build. Scale capacity modularly as your compute demand grows. 100kW Max Rack Density 1.15 Extreme PUE 4Weeks Typical Lead Time
The Product Lineup

Choose Your Scale

ISO Standard Containers
Factory Prefabricated
SERIES I (40FT)

High-Density Cluster Module

Engineered for large-scale LLM training clusters. By decoupling UPS and batteries to an external unit, we maximize internal space for compute. Combined with total 900kW in-rack liquid cooling CDU, a single container supports a 1MW supercomputing cluster.
Liquid Cooling Container Data Center 100kW Configuration
Total Load
1 MW
Rack Density
100 kW
Cooling Source
In-Rack CDU x8
Config
External Power
Liquid/Air Ratio 9:1 for extreme efficiency.
Supports 3+1 redundant In-Row AC to eliminate hotspots.
Download Series I Specs
Liquid Cooling Container Data Center 100kW Configuration
Liquid Cooling Container Data Center 60kW Configuration
SERIES II (40FT)

Integrated Standard Module

The "Plug & Play" champion. We fully integrate UPS, Lithium batteries, and liquid cooling systems into a single 40ft shell. This is the definition of rapid deployment—perfect for scenarios with limited external power infrastructure or urgent compute needs.
Liquid Cooling Container Data Center 60kW Configuration
Total Load
480 kW
Rack Density
60 kW
Cooling Source
In-Row CDU x1
Config
Internal Power
Liquid/Air Ratio 8:2 balanced cooling solution.
Built-in 600kVA Modular UPS + Battery Backup.
Download Series II Specs
SERIES III (20FT)

Edge Compact Module

Small footprint, massive power. This 20ft module is built for Edge Computing, Smart Cities, or Research Labs where space is constrained. Deploy 200kW of high-performance liquid-cooled compute anywhere—from parking lots to rooftops.
Liquid Cooling 20-Foot Container Data Center 50kW Configuration
Total Load
200 kW
Rack Density
50 kW
Cooling Source
In-Rack CDU x4
Config
Internal Power
Highly Integrated: All subsystems within 20ft.
Includes 300kVA UPS + 15min Backup Battery.
Download Series III Specs
Liquid Cooling 20-Foot Container Data Center 50kW Configuration
40-Foot AI Container Data Center 50kW per Rack Immersion Cooling
SERIES IV (40FT)

Immersion Cooling Module

The ultimate solution for harsh environments. Servers are submerged directly in dielectric fluid, eliminating fans, dust, and noise. This is the only choice for deserts, mining sites, or tropical regions, achieving extreme PUE and stability for high-performance compute.
40-Foot AI Container Data Center 50kW per Rack Immersion Cooling
Total Load
~700 kW
Rack Density
50 kW
Cooling Source
400kW CDU x2
Config
External Power
100% Heat Removal via Liquid (No fans required), Ultra-Quiet.
Ideal for Crypto Mining or Extreme HPC.
Download Series IV Specs
The Featured Components

Engineering Core

A seamless integration of industrial ruggedness and microscopic precision. Designed as a unified system, not just a collection of parts.
LAYER 01: THE FORTRESS

Industrial-Grade ISO Shell

The container is not just a box; it's the primary defense line. We re-engineer standard ISO shipping containers with reinforced steel, creating a hermetically sealed environment that protects high-value compute assets from extreme external conditions.
PROTECTION
IP65 Rated
INSULATION
R-30 Wall
LOGISTICS
CSC Certified
Modular Data Center
STRUCTURAL INTEGRITY
10 Year Lifecycle
INSIDE THE SHELL
LAYER 02: THE INTERNAL SYSTEM

Precision Liquid Loop

Controlling the manufacturing of CDUs, Manifolds, and Tanks in-house, AICoolit™ series guarantee seamless compatibility and supply chain security for your critical infrastructure.
The "heart" of the liquid cooling system. Our in-row CDUs feature 1+1 redundant pumps and smart VFD flow control. It dynamically balances pressure and flow based on real-time server load, ensuring 100% uptime and optimal thermal performance.
Dual-Pump Redundancy
Auto-Balance Logic
Leak Detection
Touchscreen HMI
Main distribution arteries fabricated from 316L Medical-Grade Stainless Steel. We utilize advanced orbital welding technology to guarantee zero-leak joints and superior corrosion resistance over a 10-year lifecycle.
316L Stainless Steel
Orbital Welding
Passivation Treatment
1.5x Pressure Tested
Blind-mate Universal Quick Disconnects fully compliant with OCP standards. Designed for safe, spill-free hot-swapping of server blades, even while the system is under pressure.
OCP Compliant
Non-Spill Tech
Blind-Mate Ready
High Cycle Life
Robust rack-level fluid transport. We offer flexible EPDM braided hoses for versatility or rigid copper tubing for permanence. Engineered for full chemical compatibility with PG25 and various dielectric fluids.
EPDM / Copper Options
High Pressure Rating
Chemical Resistance
Kink-Proof Design
SOETECK V-Shaped Integrated Outdoor Air Cooled Condenser - 1
Dry Cooler

Dry Coolers & Cooling Towers

EXTERNAL
Efficient outdoor heat rejection systems. Our Adiabatic Dry Coolers utilize smart spray assist to maintain high cooling capacity even during peak summer temperatures, while conserving water compared to traditional towers.
Water Saving
EC Fan Technology
Smart Controls
Low Noise
Trusted by Global Leaders & Standards
OCP Member
ISO 9001
CE Certified
Uptime TIER III
Supply Chain Security

Built for Scale.
Delivered Globally.

In the AI race, supply chain certainty is everything. SOETECK owns the entire manufacturing process—from sheet metal fabrication to precision liquid loop assembly. We guarantee capacity when you need it most.
50,000 m² Smart Factory
Automated production lines capable of delivering 500+ modules annually.
Global Logistics Network
Strategic partnerships with major shipping lines ensure rapid deployment to Americas, EMEA, and APAC.
data center container in soeteck factory-1
Common Questions

Expert Answers

Everything you need to know about deploying liquid-cooled modular data centers.

We employ a “Defense-in-Depth” strategy. First, our Negative Pressure design ensures that if a micro-leak occurs, air is sucked in rather than fluid spraying out. Second, intelligent leak detection sensors (rope & spot) are deployed at every manifold joint and CDU. If moisture is detected, the system instantly isolates the affected loop and alerts operators, preventing damage to IT equipment.

No. The AICoolit system is designed to be “set and forget”. Routine maintenance is minimal—primarily checking fluid levels and filters annually. Our CDUs feature self-diagnostic capabilities. For server maintenance, our non-spill UQD connectors allow IT staff to hot-swap blades just as easily as in air-cooled racks, with no special plumbing skills required.

Absolutely. Our liquid cooling architecture is specifically engineered for high-TDP chips (up to 1000W+ per socket). We support standard OCP cold plates that fit NVIDIA, AMD, and Intel accelerators. Whether you are running HGX H100 clusters or future Blackwell architectures, our 100kW/rack density provides ample thermal headroom.

Yes. The container shell is IP65 rated and R-30 insulated, decoupling the internal environment from the outside. For heat rejection, our adiabatic dry coolers maintain cooling efficiency even in ambient temperatures up to 50°C (122°F). We have successful deployments in Middle Eastern deserts and tropical Southeast Asian regions.

Traditional builds take 18-24 months. With AICoolit, we can deliver a factory-tested 1MW module in 8-12 weeks. Once on-site, installation involves simple power and water hookups, typically taking less than a week to commission. This allows you to start training your models months ahead of the competition.

Start Your AI Journey Today

Don't let infrastructure be your bottleneck.
Configure your liquid-cooled data center and get a preliminary engineering layout within 24 hours.
Free TCO Analysis Report
Custom 3D Layout Drawing
Technical Specification Sheet
Request A Quote