    Soeteck AICoolit™ Rack CDU Coolant Distribution Unit

    The Soeteck Rack CDU Coolant Distribution Unit is a versatile rack-level liquid cooling solution for small-to-medium data centers, edge computing facilities, and flexibly expandable cold-plate liquid-cooled scenarios. With multi-scenario compatibility, 50-200kW high heat-density support, and high redundancy design, it ensures efficient and safe operation.

    Cooling Capacity50-80 kW
    Inlet Flow Rate4.32-6.91 m³/h
    Outlet Flow Rate4.56-7.29 m³/h
    Rated Power0.8/1.4 kW
    Fluid TypeWater / 25% EG
    W*D*H450*850*175/536*900*175 mm
    Weight75/85 kg
       

    Product Overview

    The Soeteck Rack CDU Coolant Distribution Unit is a sophisticated rack-level liquid cooling cooltant distribution unit designed for diverse data center and edge computing scenarios. It is specifically tailored to meet the needs of small-to-medium-sized data centers, which are suitable for small-scale or decentralized liquid-cooled computing deployments (applicable to setups with more than 1 liquid-cooled cabinet).

    This CDU is also ideal for edge computing facilities, where there is limited space but a demand for high-performance liquid-cooled edge computing environments. Additionally, it fits well in cold-plate liquid-cooled computing application scenarios that require flexible expansion, as it can scale up with single cabinets as the smallest granularity.

    It boasts multi-scenario compatibility, offering two size specifications of 19 inches and 21 inches to adapt to different application scenarios. It enables high heat-density deployment, with the power density of standard cabinets supporting up to 50-200kW. Moreover, it has a high redundancy design; key sensors and pumps of the CDU adopt redundant design, which maximizes operational safety.

    Features

    Multi-Scenario Compatibility

    • Offers two size specifications of 19 inches and 21 inches, enabling adaptation to a wide variety of application scenarios, from small-scale data centers to specialized edge computing environments. This flexibility allows for seamless integration into different infrastructure setups.

    High Heat-Density Deployment

    • The power density of standard cabinets can support up to 50-200kW, which is essential for efficiently dissipating heat from high-power computing equipment in environments where space is at a premium but computing power demands are high. This ensures that servers and other hardware can operate within optimal temperature ranges even under heavy load.

    High Redundancy Design

    • Key components of the CDU, such as sensors and pumps, adopt redundant design. This means there are backup components available to take over in case of a failure, maximizing operational safety and minimizing the risk of system downtime during maintenance or component malfunction.

    Applications

    • Small-to-medium-sized data centers
    • Edge computing facilities
    • Flexibly expandable cold-plate liquid-cooled computing scenarios

    Models

    The Soeteck Rack CDU Coolant Distribution Unit is available in multiple models to meet different cooling requirements. The SY-CDU-RK-50 model offers a heat exchange capacity of 50kW, with a primary-side circulating water flow rate of 4.32 m³/h and a rated power of 0.8kW, making it suitable for smaller-scale installations. The SY-CDU-RK-80 model provides a heat exchange capacity of 80kW, a primary-side flow rate of 6.91 m³/h, and a rated power of 1.4kW, ideal for setups with higher heat loads. All models share common design principles in terms of multi-scenario compatibility and high redundancy features, while differing in key performance parameters to offer flexibility in meeting various data center and edge computing needs.

    ModelsCooling CapacityCirculation Flow RateRated PowerFluid TypePump CountWidthDepthHeightAppox.Weight
    SY-CDU-RK-5050kW4.32/4.56 m³/h0.8kWWater / 25% EGnone450mm850mm175mm75kg
    SY-CDU-RK-8080kW6.91/7.29 m³/h1.4kWWater / 25% EGnone536mm900mm175mm85kg